Microson - Facial lifting and body remodeling treatments

High Intensity Focused Ultrasound – neocollagenesis through last minute non-invasive treatment


High Intensity Focused Ultrasounds (HIFU) are delivered in the tegument, as well as on the level of the SMAS (Superficial Muscular Aponeurosis System), in the form of fasces, generating an increased temperature in the deep dermis and fibrous tissue. When the temperature surpasses 47 °C (the temperature at which proteins are denatured) the coagulation zone is generated. The affected area is filled with the near tissues and muscles, which causes an increase in the skin’s elasticity and the vanishing of wrinkles.

Download the presentation

Microson HIFU applications

  • Instant brow lifting;
  • Treatment of acne scars;
  • Improving the aspect of expression lines;
  • Increase of the skin’s elasticity through the stimulation of elastin and collagen structure;
  • Non-invasive lifting for the face, neck and décolletage;
  • Facial contouring and double chin lifting by skin tensioning;
  • Body remodeling through the reduction of the adipose layer on the abdominal area;

Focus and accuracy

The Microson HIFU is a unique system that assures different depths for facial treatments and one specific depth for body treatments.

SD7 – 1.5 mm

Decreasing of wrinkles through the promotion of neocollagenesis in the superior dermal layers and TCP in the layers rich in collagen until a depth of 1.5mm

DD7 – 3.0mm

Facial lifting and collagen regeneration through the creation of TCP (Thermal Coagulation Points) in the deep dermis (3.0mm).

SM4 – 4.5mm

Non-invasive facial lifting through the production of TCP in the SMAS. SMAS covers the facial musculature and is approximately at a 4.5 mm depth in the subcutaneous layer. SMAS is made of collagen and elastic fibers and has the role of transmitting muscle contractions towards the facial surface.

SC4 – 13mm

Fat reduction through HIFU treatments in the area of the glutes and abdominals. The increase in temperature of the adipose layer can lead to it’s reduction due to the necrotic coagulation of the adipocytes at a temperature of 56 ºC or above.

Optimized transducers in 5 different versions

transcendere
FaceBody
TransducerSM4-4.5DD7-3.0SD7-1.5SD7-1.5NSC4-13
Frequency4MHz7MHz7MHz7MHz4MHz
Depth4.5mm3.0mm1.5mm1.5mm13mm
Targeted areaSMASDeep dermisSuperficial dermisSuperficial dermisSubcutaneous layer

Technical specifications

EnergyHigh Intensity Focused Ultrasound (HIFU)
TransducerSM4-4.5 // DD7-3.0 // SD7-1.5 // SD7-1.5N // SC4-13
Spacing3 density levels
Length25mm (Max.)
Electrical requirementsAC 100-240V @ 50/60Hz
Display10.2 inch touchscreen
Weight26kg
Dimensions471 x 477 x 1227mm
ManufacturerEunsung Global Corp.